{"product_id":"fl24117-fleck-5600-valve-standard-piston-range-grey-cap-low-waste-water-copy","title":"FL24117 - Fleck 5600 Valve Standard Piston Range Grey Cap - Low Waste Water","description":"\u003ch3 data-start=\"503\" data-end=\"564\"\u003eFleck 5600 Standard Piston – Grey Cap (Low Waste Water)\u003c\/h3\u003e\n\u003cp data-start=\"565\" data-end=\"589\"\u003e\u003cstrong data-start=\"565\" data-end=\"589\"\u003ePart Number: FL24117\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"591\" data-end=\"896\"\u003eThe \u003cstrong data-start=\"595\" data-end=\"635\"\u003eFleck 5600 Grey Cap Piston (FL24117)\u003c\/strong\u003e is a genuine replacement piston designed for \u003cstrong data-start=\"681\" data-end=\"744\"\u003eolder-style Fleck 5600 mechanical Econominder control heads\u003c\/strong\u003e. This version features a \u003cstrong data-start=\"770\" data-end=\"796\"\u003elow waste water design\u003c\/strong\u003e, helping to reduce water usage during regeneration while maintaining reliable softener performance.\u003c\/p\u003e\n\u003cp data-start=\"898\" data-end=\"1100\"\u003e⚠️ \u003cstrong data-start=\"901\" data-end=\"915\"\u003eImportant:\u003c\/strong\u003e Fleck 5600 pistons are \u003cstrong data-start=\"939\" data-end=\"955\"\u003ecolour coded\u003c\/strong\u003e and must always be replaced \u003cstrong data-start=\"984\" data-end=\"1001\"\u003elike-for-like\u003c\/strong\u003e. Installing an incorrect piston colour may result in inefficient operation or regeneration issues.\u003c\/p\u003e\n\u003chr data-start=\"1102\" data-end=\"1105\"\u003e\n\u003ch3 data-start=\"1107\" data-end=\"1150\"\u003eAvailable Fleck 5600 Mechanical Pistons\u003c\/h3\u003e\n\u003cul data-start=\"1152\" data-end=\"1251\"\u003e\n\u003cli data-start=\"1152\" data-end=\"1179\"\u003e\n\u003cp data-start=\"1154\" data-end=\"1179\"\u003e\u003cstrong data-start=\"1154\" data-end=\"1177\"\u003eFL24116 – White Cap\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1180\" data-end=\"1206\"\u003e\n\u003cp data-start=\"1182\" data-end=\"1206\"\u003e\u003cstrong data-start=\"1182\" data-end=\"1204\"\u003eFL18089 – Blue Cap\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1207\" data-end=\"1251\"\u003e\n\u003cp data-start=\"1209\" data-end=\"1251\"\u003e\u003cstrong data-start=\"1209\" data-end=\"1249\"\u003eFL24117 – Grey Cap (Low Waste Water)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1253\" data-end=\"1366\"\u003e👉 Always choose the piston that \u003cstrong data-start=\"1286\" data-end=\"1332\"\u003ematches the colour of your existing piston\u003c\/strong\u003e, as shown in the reference image.\u003c\/p\u003e\n\u003chr data-start=\"1368\" data-end=\"1371\"\u003e\n\u003ch3 data-start=\"1373\" data-end=\"1408\"\u003eCompatibility \u0026amp; Important Notes\u003c\/h3\u003e\n\u003cul data-start=\"1410\" data-end=\"1760\"\u003e\n\u003cli data-start=\"1410\" data-end=\"1483\"\u003e\n\u003cp data-start=\"1412\" data-end=\"1483\"\u003e✔️ Compatible with \u003cstrong data-start=\"1431\" data-end=\"1483\"\u003eFleck 5600 mechanical Econominder control valves\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1484\" data-end=\"1561\"\u003e\n\u003cp data-start=\"1486\" data-end=\"1561\"\u003e❌ \u003cstrong data-start=\"1488\" data-end=\"1504\"\u003eNot suitable\u003c\/strong\u003e for Fleck 5600 \u003cstrong data-start=\"1520\" data-end=\"1527\"\u003eSXT\u003c\/strong\u003e or older \u003cstrong data-start=\"1537\" data-end=\"1561\"\u003eSE electronic valves\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1562\" data-end=\"1622\"\u003e\n\u003cp data-start=\"1564\" data-end=\"1622\"\u003eDifferent Fleck 5600 valves use \u003cstrong data-start=\"1596\" data-end=\"1622\"\u003edifferent drive motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1623\" data-end=\"1760\"\u003e\n\u003cp data-start=\"1625\" data-end=\"1661\"\u003eFitting the wrong piston colour may:\u003c\/p\u003e\n\u003cul data-start=\"1664\" data-end=\"1760\"\u003e\n\u003cli data-start=\"1664\" data-end=\"1695\"\u003e\n\u003cp data-start=\"1666\" data-end=\"1695\"\u003eReduce softening efficiency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1698\" data-end=\"1728\"\u003e\n\u003cp data-start=\"1700\" data-end=\"1728\"\u003eIncrease water consumption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1731\" data-end=\"1760\"\u003e\n\u003cp data-start=\"1733\" data-end=\"1760\"\u003eCause regeneration faults\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1762\" data-end=\"1881\"\u003e➡️ \u003cstrong data-start=\"1765\" data-end=\"1808\"\u003eFor electronic Fleck valves (SXT or SE)\u003c\/strong\u003e, please select the \u003cstrong data-start=\"1828\" data-end=\"1863\"\u003eelectronic piston and seal kits\u003c\/strong\u003e, sold separately.\u003c\/p\u003e\n\u003chr data-start=\"1883\" data-end=\"1886\"\u003e\n\u003ch3 data-start=\"1888\" data-end=\"1904\"\u003eKey Benefits\u003c\/h3\u003e\n\u003cul data-start=\"1906\" data-end=\"2154\"\u003e\n\u003cli data-start=\"1906\" data-end=\"1945\"\u003e\n\u003cp data-start=\"1908\" data-end=\"1945\"\u003eLow waste water regeneration design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1946\" data-end=\"1995\"\u003e\n\u003cp data-start=\"1948\" data-end=\"1995\"\u003eRestores correct valve timing and performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1996\" data-end=\"2051\"\u003e\n\u003cp data-start=\"1998\" data-end=\"2051\"\u003eDirect replacement – no valve modification required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2052\" data-end=\"2089\"\u003e\n\u003cp data-start=\"2054\" data-end=\"2089\"\u003eGenuine Fleck water softener part\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2090\" data-end=\"2154\"\u003e\n\u003cp data-start=\"2092\" data-end=\"2154\"\u003eIdeal for servicing and maintaining older Econominder valves\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2156\" data-end=\"2159\"\u003e\n\u003ch3 data-start=\"2161\" data-end=\"2185\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul data-start=\"2187\" data-end=\"2366\"\u003e\n\u003cli data-start=\"2187\" data-end=\"2263\"\u003e\n\u003cp data-start=\"2189\" data-end=\"2263\"\u003eDomestic water softeners using \u003cstrong data-start=\"2220\" data-end=\"2263\"\u003eFleck 5600 mechanical Econominder heads\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2264\" data-end=\"2305\"\u003e\n\u003cp data-start=\"2266\" data-end=\"2305\"\u003eReplacement of worn or sticking pistons\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2306\" data-end=\"2366\"\u003e\n\u003cp data-start=\"2308\" data-end=\"2366\"\u003eImproving regeneration efficiency and reducing water waste\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2368\" data-end=\"2371\"\u003e\n\u003ch3 data-start=\"2373\" data-end=\"2387\"\u003eNeed Help?\u003c\/h3\u003e\n\u003cp data-start=\"2389\" data-end=\"2640\"\u003eIf you’re unsure which piston you need, simply \u003cstrong data-start=\"2436\" data-end=\"2487\"\u003echeck the colour of the piston currently fitted\u003c\/strong\u003e or contact \u003cstrong data-start=\"2499\" data-end=\"2515\"\u003eWrekin Water\u003c\/strong\u003e for expert technical advice. We stock a full range of \u003cstrong data-start=\"2570\" data-end=\"2617\"\u003eFleck water softener parts and valve spares\u003c\/strong\u003e and are happy to help.\u003c\/p\u003e","brand":"Fleck","offers":[{"title":"Default Title","offer_id":53570921300297,"sku":"0401187224-FL24117","price":30.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/0235\/9625\/files\/5600_Grey_Piston_500px.jpg?v=1766680591","url":"https:\/\/wrekinwatertreatment.co.uk\/products\/fl24117-fleck-5600-valve-standard-piston-range-grey-cap-low-waste-water-copy","provider":"WrekinWater","version":"1.0","type":"link"}