Product Description
The FL24116 standard piston is the genuine internal piston assembly fitted to Fleck 5600 control valves in the White Cap standard regeneration range, directing water through the service, backwash, brine draw and rinse stages of every cycle. WrekinWater stocks this replacement piston for customers whose valve is leaking to drain, sticking mid-cycle or failing to complete regenerations correctly.
Technical specifications
| Part Number | FL24116 |
| Brand | Pentair Fleck |
| Compatible Valve | Fleck 5600, White Cap standard regeneration range |
| Part Type | Valve piston assembly |
| Material | Reinforced plastic with rubber seals and spacers |
| Function | Directs water flow through each stage of the regeneration cycle |
Symptoms that mean you need this part
- Water continuously leaks or trickles from the drain line, even during normal service
- The valve gets stuck partway through a regeneration cycle
- Hardness is breaking through even though salt levels and resin are fine
- The valve makes a grinding or sticking noise as it cycles through positions
Why it fails / why it matters
The piston sits inside the valve body and slides back and forth on the seal and spacer stack, opening and closing the correct ports for each stage of regeneration. Iron, grit and years of chlorinated mains water gradually wear or score the seals and spacers, allowing water to bypass to drain when it shouldn't, or preventing the piston travelling its full range so the valve hangs mid-cycle.
Why buy this from WrekinWater
WrekinWater has served more than 50,000 customers over 15 years from Bettisfield, Shropshire, and stocks genuine Pentair Fleck pistons, seal kits and couplings alongside Autotrol, Clack and Kinetico spares. As a UK company (Company No. 11000488) rated Excellent on Trustpilot, we help confirm your valve is the White Cap standard regen range before you order.
How to fit it
- Turn off the water supply and place the valve in bypass, relieving system pressure
- Remove the headwork retaining clips or screws to access the piston assembly
- Withdraw the old piston, seal and spacer stack from the valve body
- Inspect the valve body bore for scoring or debris and clean if needed
- Fit the new FL24116 piston assembly, confirming it matches the White Cap standard regen range
- Reassemble the headwork, restore the water supply and run a manual regeneration to confirm smooth cycling
Technical Resources
Frequently asked questions