To change reverse osmosis filters: turn off the feed and tank valves, open the RO tap to release pressure, unscrew the filter housings, fit new cartridges with clean O-rings, then turn the water back on, check for leaks and flush the first tank of water away. Most people can do it in 20 to 30 minutes. This guide covers standard housing systems and quick-change systems, plus the membrane.

Written by the Wrekin Water team, Bettisfield, Shropshire. Last updated November 2026.

20–30 min
Typical time for a filter change
Yearly
Pre- and post-filters, at least
2–3 yrs
RO membrane
1–2 tanks
Flush to waste after changing

When to change each filter

Sediment pre-filter6–12 months
Carbon pre-filters6–12 months
Carbon post-filter12 months
Remineralising filter12 months
UV lamp (if fitted)12 months
RO membrane24–36 months

Typical intervals. Hard or dirty water and heavy use mean more frequent changes.

Part Signs it is due
Sediment pre-filter Discoloured cartridge, slower flow
Carbon pre-filters Chlorine taste returns. These protect the membrane, so do not stretch this one
RO membrane Slower production, TDS reading creeping up, scale returning in the kettle
Carbon post-filter Stale or flat taste
UV lamp Lamps lose strength before they stop glowing, so change on time

A cheap TDS meter is the easiest way to check the membrane: compare tap water and RO water. If the reduction drops noticeably from when the system was new, the membrane is due. Never miss a change: join our free filter reminder service.

What you need

Replacement set
for your system
Housing spanner
usually supplied
Bucket and towels
for spills
Silicone grease
food-grade, for O-rings
Disposable gloves
clean hands on filters
Washing-up liquid
mild, unperfumed

Find the right replacement filters

Also see the 4-stage ACRO4 set and all domestic RO filters. Not sure which you have? Send us a photo of your system and we will match it.

Which type of system do you have?

Standard housing reverse osmosis system with clear filter bowlsStandard housings

Screw-off bowls holding 10-inch cartridges, a horizontal membrane housing and inline post-filters. Follow the full steps below.

Kinetico quick change cartridge RO systemQuick-change cartridges

Kinetico, Spectrum Z1 and Ecosoft CROSS. Twist off, twist on. Jump to quick-change systems.

Changing pre-filters on a standard housing system

1
Shut off the water. Close the feed valve to the RO system and the valve on top of the storage tank.
2
Release the pressure. Open the RO tap until the flow stops. Put the bucket and towels under the housings.
3
Remove the housings. Unscrew each bowl with the spanner, turning anticlockwise when viewed from below. Expect some water.
4
Take out the old cartridges and note which goes where: sediment first, then carbon.
5
Clean the bowls with warm water and a drop of washing-up liquid, then rinse well.
6
Check the O-rings. Wipe them, smear with food-grade silicone grease and seat them fully in their groove. A twisted or dry O-ring is the most common cause of leaks.
7
Fit the new cartridges wearing gloves, in the correct order, centred on the spigots.
8
Refit the bowls hand-tight, then a quarter turn with the spanner. Do not overtighten.

Changing the RO membrane

Reverse osmosis membrane element showing the end with two O-rings
1
With the water still off, disconnect the tube from the end cap of the membrane housing: press the collet and pull the tube.
2
Unscrew the end cap.
3
Pull the old membrane out with pliers. Note which end went in first.
4
Wearing gloves, push the new membrane in the same way round, with the end carrying the two small O-rings going in first, until it is fully seated.
5
Refit the cap hand-tight and reconnect the tube.

Changing inline post-filters

Inline filters have push-fit connections. Press the collet, pull the tube out at each end, and fit the new filter with the flow arrow pointing towards the tap. Push the tubes in firmly until they stop.

Quick-change systems

Spectrum Z1 twist-fit cassette

Kinetico, Spectrum Z1 and Ecosoft CROSS systems use twist-off cartridges. Turn off the feed, twist the old cartridge a quarter turn and pull it out, then push and twist the new one in. No housings or O-rings to deal with.

Starting the system again

Open feed slowly→ Check for drips→ Open tank valve→ Let tank fill→ Flush first tank→ Use as normal

Open the feed valve slowly and check every joint for drips over the next few minutes. Open the tank valve and close the RO tap. Let the tank fill (a few hours), then run the whole tank to waste to flush out carbon fines and membrane preservative. For a new membrane, flush a second tank as well.

Air in the system after a filter change can make water look cloudy or spit from the tap for a day or two. This is normal and clears on its own.

Should I sanitise my RO system?

Many manufacturers recommend sanitising once a year, usually when changing the pre-filters. Always remove the membrane first, follow your system's instructions and use a sanitiser approved for drinking water systems.

Something not right after the change? See our RO troubleshooting guide or go back to the complete UK guide to reverse osmosis.

Frequently asked questions

Change the sediment and carbon pre-filters every 6 to 12 months, the post-filter and any remineralising filter every 12 months, and the RO membrane every 2 to 3 years. Hard or dirty water and heavy use mean more frequent changes.

Yes. Pre-filters and post-filters are usually changed yearly and the membrane every two to three years. Changing the pre-filters on time is the best way to make the membrane last.

Not always. Many systems take standard 10-inch cartridges and 1812 size membranes. Check the size, connection type and micron rating, or send us a photo and we will match it.

Tiny air bubbles trapped during the change. Leave a glass to stand and it clears from the bottom up. It settles on its own within a day or two.

Make sure the pressure is fully released by closing the feed valve and opening the RO tap, then use the proper housing spanner. Never use a pipe wrench on plastic housings, as it can crack them.