CR200 - Evolve Simplex 1" Valve - Crystal-Right Iron and Manganese
CR200 - Evolve Simplex 1" Valve - Crystal-Right Iron and Manganese
SKU:15407000140-C00001
Share
Evolve Water Filtration System with Crystal Right CR200 Media
The Evolve water filter system is an advanced solution for treating problem water containing iron, manganese, ammonia, and hardness. Engineered with a built-in chlorine generator, the system self-sanitises during regeneration—producing chlorine to disinfect the media bed and prevent bacteria and odour build-up.
At the heart of the system is Crystal Right CR200, a powerful synthetic zeolite media that simultaneously:
-
Reduces iron, manganese, ammonia, and hardness
-
Raises low pH (pH ≥ 7 required)
-
Operates via salt-based regeneration
This all-in-one solution offers outstanding performance for homes or businesses dealing with complex water quality issues.
🔬 Key Features
✅ Crystal Right CR200 Media – Removes iron, manganese, ammonia, and hardness in one pass
✅ Raises Low pH – Ideal for slightly acidic water (minimum pH 7)
✅ Built-in Chlorine Generator – Disinfects media during regeneration to prevent bacteria and odours
✅ Optional KDF Media – Add-on available to treat hydrogen sulphide (H₂S)
✅ Salt/Brine Regeneration – Simple and effective backwash process
✅ Self-cleaning & Low Maintenance – Long media life and minimal intervention required
✅ Ideal for Private Wells and Boreholes
⚙️ System Requirements
To ensure optimal performance of the Crystal Right media:
-
Minimum pH: 7 for CR200
-
Minimum Hardness: 50 ppm (as CaCO₃)
-
Minimum TDS: 80 ppm
-
Maximum Iron + Manganese: 15 ppm combined
-
Water must be clear (no oxidised iron/manganese)
🔄 CR100 vs CR200 – Which Should You Choose?
Media Type | pH Range | Use When… |
---|---|---|
CR100 | 6.0 to <7.0 | Your water is acidic and pH is between 6 and 7; removes iron, manganese, ammonia, hardness |
CR200 | 7.0 and above | Your water pH is neutral or above; also raises pH, treats same contaminants |
💡 Need help testing your water? Ask us about our home water testing kits or on-site assessment services.
❓ Frequently Asked Questions (FAQs)
Q: What is Crystal Right media?
A: Crystal Right is a synthetic silica zeolite that reduces iron, manganese, ammonia, hardness, and even raises low pH. It's regenerated using salt/brine and works best on clear (dissolved) contaminants.
Q: Can this system remove hydrogen sulphide (rotten egg smell)?
A: Not directly. However, by adding KDF media, the system can remove H₂S effectively if concentrations are low. Crystal Right alone is not recommended for H₂S above 0.5 ppm.
Q: Does the Evolve valve need maintenance?
A: The Evolve valve features a built-in chlorine generator that automatically disinfects the media, reducing bacterial slime and odours. Maintenance is minimal, mainly topping up salt and periodic media checks.
Q: What are the signs I need CR100 instead of CR200?
A: Choose CR100 if your raw water has a pH between 6.0 and 7.0. Use CR200 if the pH is already 7 or above, or you also need pH correction in slightly acidic water.
Additional Product Info
Additional Product Info



CR200 - Evolve Simplex 1" Valve - Crystal-Right Iron and Manganese

CR200 - Evolve Simplex 1" Valve - Crystal-Right Iron and Manganese
Evolve Water Filtration System with Crystal Right CR200 Media
The Evolve water filter system is an advanced solution for treating problem water containing iron, manganese, ammonia, and hardness. Engineered with a built-in chlorine generator, the system self-sanitises during regeneration—producing chlorine to disinfect the media bed and prevent bacteria and odour build-up.
At the heart of the system is Crystal Right CR200, a powerful synthetic zeolite media that simultaneously:
-
Reduces iron, manganese, ammonia, and hardness
-
Raises low pH (pH ≥ 7 required)
-
Operates via salt-based regeneration
This all-in-one solution offers outstanding performance for homes or businesses dealing with complex water quality issues.
🔬 Key Features
✅ Crystal Right CR200 Media – Removes iron, manganese, ammonia, and hardness in one pass
✅ Raises Low pH – Ideal for slightly acidic water (minimum pH 7)
✅ Built-in Chlorine Generator – Disinfects media during regeneration to prevent bacteria and odours
✅ Optional KDF Media – Add-on available to treat hydrogen sulphide (H₂S)
✅ Salt/Brine Regeneration – Simple and effective backwash process
✅ Self-cleaning & Low Maintenance – Long media life and minimal intervention required
✅ Ideal for Private Wells and Boreholes
⚙️ System Requirements
To ensure optimal performance of the Crystal Right media:
-
Minimum pH: 7 for CR200
-
Minimum Hardness: 50 ppm (as CaCO₃)
-
Minimum TDS: 80 ppm
-
Maximum Iron + Manganese: 15 ppm combined
-
Water must be clear (no oxidised iron/manganese)
🔄 CR100 vs CR200 – Which Should You Choose?
Media Type | pH Range | Use When… |
---|---|---|
CR100 | 6.0 to <7.0 | Your water is acidic and pH is between 6 and 7; removes iron, manganese, ammonia, hardness |
CR200 | 7.0 and above | Your water pH is neutral or above; also raises pH, treats same contaminants |
💡 Need help testing your water? Ask us about our home water testing kits or on-site assessment services.
❓ Frequently Asked Questions (FAQs)
Q: What is Crystal Right media?
A: Crystal Right is a synthetic silica zeolite that reduces iron, manganese, ammonia, hardness, and even raises low pH. It's regenerated using salt/brine and works best on clear (dissolved) contaminants.
Q: Can this system remove hydrogen sulphide (rotten egg smell)?
A: Not directly. However, by adding KDF media, the system can remove H₂S effectively if concentrations are low. Crystal Right alone is not recommended for H₂S above 0.5 ppm.
Q: Does the Evolve valve need maintenance?
A: The Evolve valve features a built-in chlorine generator that automatically disinfects the media, reducing bacterial slime and odours. Maintenance is minimal, mainly topping up salt and periodic media checks.
Q: What are the signs I need CR100 instead of CR200?
A: Choose CR100 if your raw water has a pH between 6.0 and 7.0. Use CR200 if the pH is already 7 or above, or you also need pH correction in slightly acidic water.