Skip to product information
1 of 4

Autotrol Magnum IT-762 (298) Softener Valve with Metered control 2"

Autotrol Magnum IT-762 (298) Softener Valve with Metered control 2"

SKU:10345000012-C00003-Softener-Metered

Regular price £1,460.00 inc. VAT
£1,216.67 ex. VAT
Sale price £1,460.00 inc. VAT
£1,216.67 ex. VAT
Shipping calculated at checkout.
Shipping is calculated at checkout
Please ensure you order the correct Water Softener/Filter/Valve parts and Media as returns are not available for these products, as per our Terms and conditions and refund/return policy.
If you would like delivery to Scottish Highlands or UK Offshore Areas.Please contact us for Accurate Shipping charges. Call Now
Order Before 2pm For Same Day Processing

Product Description

The Magnum IT-762 (298) is Autotrol's high-flow 2" control valve built for commercial and industrial water softening applications where a standard 1" or 1.25" valve simply can't cope with the throughput. Fitted with metered (demand-initiated) control, it tracks actual water usage through the system and triggers regeneration only when the resin bed's capacity is genuinely exhausted, rather than on a fixed time clock, which keeps salt and water use down on high-demand sites. This is a complete replacement valve assembly, supplied ready to fit to a Magnum-format tank, and is stocked by WrekinWater for installers and site engineers who need to get a large-format softener back in service with minimal downtime.

Technical specifications

OEM Part Number 10345000012-C00003
Valve Series Magnum IT-762 (298)
Port Size 2" (BSP)
Control Type Metered (meter immediate / meter delayed regeneration)
Application Commercial & industrial water softening
Regeneration Cycle Backwash, brine draw & slow rinse, fast rinse, brine refill
Brand Autotrol

Symptoms that mean you need this part

  • The valve won't complete a regeneration cycle or repeatedly hangs partway through, and seal or piston kits haven't resolved it
  • The main valve body is cracked, split or leaking at multiple points rather than a single seal
  • The site's water demand has outgrown the valve's rated flow capacity, causing pressure drop at peak usage
  • You're replacing an old mechanical time-clock valve with metered control to cut salt and water consumption
  • The drive, meter or timer assembly has failed and diagnosis points to a worn valve body rather than a single component

Why it fails / why it matters

On a commercial or industrial softener, the 2" control valve is the single component that directs the entire system's flow through the resin bed and manages every stage of regeneration, so it sees far higher flow volumes and cycle counts than a domestic valve over its working life. Constant high-pressure cycling gradually wears the valve body, seal stack and injector system beyond what a service kit can restore, and once wear reaches that point the only reliable fix is a full valve replacement rather than piecemeal repairs. Fitting a complete Magnum IT-762 assembly restores full metered control and rated flow capacity in one changeover, rather than chasing intermittent faults across an ageing valve.

Why buy this from WrekinWater

WrekinWater has supported installers and commercial water treatment engineers for over 15 years from its Bettisfield, Shropshire base, serving more than 50,000 customers and stocking the full range of Pentair Fleck, Autotrol, Clack and Kinetico equipment. Because a commercial valve of this size represents a significant investment and downtime cost, WrekinWater processes orders quickly and is rated Excellent on Trustpilot, giving installers confidence that the replacement valve they receive matches what was specified.

How to fit it

  1. Isolate the softener at the bypass valve and shut down mains flow before starting any work
  2. Photograph and note the existing pipework, drain, brine line and wiring configuration before disconnecting anything
  3. Have a competent installer or commercial water treatment engineer confirm the Magnum IT-762 matches your tank thread, riser tube diameter and site flow requirements before fitting
  4. Disconnect the drain line, brine line and control wiring from the existing valve and remove it from the tank
  5. Fit the new Magnum IT-762 assembly to the tank with new manifold gaskets, and reconnect drain, brine and wiring
  6. Reprogram the meter settings — resin volume, hardness and regeneration parameters — to match your system before commissioning
  7. Restore mains supply, run a manual regeneration cycle, and check all connections for leaks before returning the system to service

Frequently asked questions

It means the valve regenerates based on actual measured water usage rather than a fixed daily timer, so the softener only regenerates when the resin bed's capacity has genuinely been used, saving salt and water on variable-demand commercial sites.

This is a complete Magnum IT-762 control valve assembly, not a seal or piston kit. It's intended for situations where the existing valve body is worn out or has outgrown the site's demand and needs replacing as a whole unit.

It's built to the Magnum IT-762 (298) format, so compatibility depends on matching tank thread and riser configuration. WrekinWater recommends having a commercial engineer confirm fit against your existing installation before ordering.

Autotrol Magnum IT-762 (298) Softener Valve with Metered control 2"

Autotrol Magnum IT-762 (298) Softener Valve with Metered control 2"

Regular price £1,460.00 inc. VAT
£1,216.67 ex. VAT
Sale price £1,460.00 inc. VAT
£1,216.67 ex. VAT