Product Description
The Fleck 25155 is the genuine piston assembly with integrated bypass for Fleck 2850 water softener control valves, suitable for both standard and hot water rated units, and WrekinWater supplies it to get 2850-based softeners sealing and cycling correctly again after years of service.
Technical specifications
| Part Number | 25155 |
| OEM Reference | 10444000247 |
| Brand | Pentair Fleck |
| Compatible Valve | Fleck 2850 series |
| Includes | Integrated bypass assembly |
| Suitable For | Standard and hot water applications |
| Material | Noryl piston body with rubber seal stack |
Symptoms that mean you need this part
- Water continues to leak or run to drain when the softener should be sitting idle in service mode
- The valve struggles to complete a full regeneration cycle, stalling or reversing unexpectedly
- Switching the valve to bypass doesn't fully isolate the softener, and water still passes through the resin
- The old piston or bypass shows visible wear, scoring or a stuck bypass lever when removed
Why it fails / why it matters
The 25155 combines the main service piston with the valve's bypass mechanism in one assembly, so wear affects both regeneration cycling and your ability to isolate the softener from the mains supply. Constant friction against the seal stack, combined with mineral fines and, on hot water models, elevated operating temperatures, gradually wears the piston surface and bypass seals until the assembly can no longer seat tightly - leading to leaks, incomplete cycles or a bypass that no longer fully isolates the unit.
Why buy this from WrekinWater
WrekinWater has served more than 50,000 customers over 15 years from Bettisfield, Shropshire, and as UK Company No. 11000488 we stock genuine Pentair Fleck parts alongside Autotrol, Clack, Kinetico and other major brands, rated Excellent on Trustpilot. Because this part covers both standard and hot water 2850 valves, we can help confirm which version your system needs before you order.
How to fit it
- Turn off the water supply and switch the control valve to bypass if it's still functioning
- Remove the top retaining cap or clip to access the piston and bypass assembly
- Carefully withdraw the worn piston and bypass unit from the valve body
- Fit the new 25155 assembly, checking the orientation of both the piston and bypass lever match the original
- Refit the retaining cap or clip securely
- Restore the water supply, cycle the bypass and run a manual regeneration to confirm smooth operation with no leaks
Technical Resources