The Harvey G3258 H25 Service Meter is the "brain" of your mechanical water softener. It is responsible for precisely measuring water consumption to trigger a regeneration cycle at the optimal moment. Once triggered, control is handed over to the regeneration meter to manage the brine draw and resin cleaning process.
⚠️ Compatibility Warning
-
Models: Specifically designed for Harvey H25 series twin tank softeners.
-
Note: This part is not suitable for the newer H20b or H20c models.
Key Symptoms: Why Replace the G3258?
While a softener "running to drain" is often a shuttle valve issue, a faulty Service Meter manifests in more specific ways:
-
Hard Water Intermittently: If the meter fails to measure consumption, the system won't trigger a regeneration, leading to hard water passing through the system.
-
Incorrect Regeneration Timing: The system regenerates too frequently (wasting salt) or not often enough.
-
Salt Bin Overfilling: If the regeneration cycle is not being initiated or completed correctly due to meter failure, the brine tank levels may become erratic.
-
Complete Cycle Failure: If the Service Meter fails to "hand over" control to the Regeneration Meter, the system will stall.
Step-by-Step Troubleshooting & Airlock Fix
If your softener is continually running to drain, we recommend replacing the G1491 Shuttle Valve first. If issues persist after a shuttle change, you may have an airlock. Follow these steps to flush the system:
-
Isolate: Turn off both the Inlet and Outlet valves.
-
Depressurize: Open the nearest softened water tap.
-
Sequence: Open the Outlet valve first.
-
Flush: Slowly open the Inlet valve. You will hear air being expelled through the tap. Continue until the flow is steady.
-
Test: Manually run the regeneration cycle twice to ensure the air is fully purged and the meters are engaging.
-
Next Step: If salt bin issues or drainage faults continue after these steps, replace the G3258 Service Meter Assembly.