Product Description
The Fleck 26775 is the genuine 230V/50Hz, 30rpm replacement motor for Fleck 5600 series control valves, also referenced as part 18824, and it's the drive unit that turns the piston through each stage of the regeneration cycle. WrekinWater supplies this exact motor for softener owners whose 5600 valve has stopped cycling, stalled mid-regeneration, or is making an unfamiliar grinding or humming noise, all classic signs of a failing drive motor rather than a wider valve fault.
Technical specifications
| Part Number | 26775 (18824) |
| Compatible Valve | Fleck 5600 |
| Voltage | 230V |
| Frequency | 50Hz |
| Speed | 30rpm |
| Brand | Pentair Fleck |
| Function | Drives the piston through the regeneration cycle |
Symptoms that mean you need this part
- The valve fails to advance through its regeneration cycle at all
- A continuous humming or grinding noise comes from the valve with no movement
- The cycle stalls partway through, leaving the softener stuck between positions
- The timer display shows the correct time but regeneration never actually starts
Why it fails / why it matters
The motor turns a gear train that indexes the piston through each stage of regeneration, and it runs this cycle continuously through years of daily use. Motors of this type are prone to wear in their internal gearing, and moisture ingress or age can cause the windings or gears to fail outright. Once the motor loses torque or seizes, it can no longer turn the piston through the valve body, so the timer may still count down correctly while the mechanical side of the softener simply stops responding, leaving the resin bed unregenerated and the water hard.
Why buy this from WrekinWater
WrekinWater has served more than 50,000 customers over 15 years from our Shropshire base, and we stock genuine Pentair Fleck motors alongside Autotrol, Clack and Kinetico parts so you're fitting an exact replacement rather than a generic 230V motor that may not match the 5600's gearing or speed. Rated "Excellent" on Trustpilot, our team is on hand if you're unsure whether it's the motor or another component causing your fault.
How to fit it
- Isolate the electrical supply to the softener before doing anything else.
- Turn off the water supply and put the valve into bypass if fitted.
- Locate the motor on the front of the valve body, usually held by two screws.
- Disconnect the motor's electrical connector and remove the retaining screws.
- Fit the new 26775 motor, reconnect the electrical connector, and secure with the screws.
- Restore power and water supply, then run a manual regeneration to confirm the valve cycles smoothly.