Product Description
The Clack WS1.5CI Softener timer controlled valve, supplied by WrekinWater, is a complete 1.5" cast-iron control valve built for large commercial water softening applications, regenerating on a fixed, programmable time-clock schedule. It's the correct full-assembly replacement for high-flow commercial installations where the existing valve has become unreliable and predictable, scheduled regeneration is preferred over metered control.
Technical specifications
| Valve Model | Clack WS1.5CI, timer (BTZ) control |
| Connection Size | 1.5" (large bore, commercial/industrial flow rates) |
| Control Type | Time clock — regenerates on a fixed, programmable schedule |
| Body Material | Cast iron construction for continuous, high-duty softening |
| Application | Large commercial and industrial water softening systems |
| Regeneration | Set time-of-day regeneration, independent of metered usage |
Symptoms that mean you need this part
- Hard water breakthrough at commercial scale despite the softener appearing to run its cycles
- The cast iron valve body shows corrosion, cracking or leaks that repair kits can no longer resolve
- The timer motor or electronic controller has failed, drifted out of sync, or is obsolete
- Regeneration cycles are inconsistent, stall partway through, or persistent faults keep recurring
Why it fails / why it matters
A timer-controlled commercial softener valve regenerates on a fixed schedule regardless of demand, so the piston, seals and timer drive mechanism cycle continuously day after day, and after years of sustained high-volume use these components wear to the point where individual seal kits no longer restore dependable, on-schedule regeneration. Once the cast iron body has corroded or the timer can no longer hold an accurate schedule, regeneration becomes unreliable at exactly the times a commercial site depends on it, making a full valve replacement the dependable fix.
Why buy this from WrekinWater
WrekinWater has served more than 50,000 customers over 15 years from our base in Bettisfield, Shropshire, and we stock genuine Clack CI valve assemblies for large commercial softening installations alongside Pentair Fleck, Autotrol and Kinetico ranges. Rated "Excellent" on Trustpilot and registered as UK Company No. 11000488, we can help confirm this valve is the correct replacement for your existing system before you order.
How to fit it
- Have a competent installer or water treatment engineer survey your existing system and confirm tank head thread, flow demand and resin volume match this 1.5" timer valve.
- Isolate the water supply and fully depressurise the softener vessel before removing the existing valve.
- Remove the old control valve from the tank head, recording inlet, outlet, drain and brine line connections.
- Fit the new Clack WS1.5CI timer valve to the tank head with new O-rings/seals, ensuring the riser tube is correctly seated.
- Reconnect drain and brine pipework, restore the water supply gradually and pressure-test every joint for leaks.
- Program the controller with the correct regeneration time, frequency and salt dose, then run a full commissioning cycle before returning the system to service.