QS-950 - Domed End Compatible Viqua Sterilight Quartz Sleeve, SPV-950, SPV-20, and SP950-HO (QJ231082DE)
QS-950 - Domed End Compatible Viqua Sterilight Quartz Sleeve, SPV-950, SPV-20, and SP950-HO (QJ231082DE)
SKU:QJ231082DE-QSO-950 (Domed End)
In stock
Share
Product Description
Product Description
Sterilight QS-950 Quartz Sleeve – Compatible with Viqua & Sterilight UV Systems
High-Transmittance UV Quartz Sleeve for Reliable Water Sterilisation
The Sterilight QS-950 Quartz Sleeve is a high-quality, domed UV quartz sleeve designed to protect and house the UV lamp within Viqua / Sterilight Platinum and Cobalt series UV systems. Manufactured from high-transmittance quartz glass, this sleeve ensures maximum UV light penetration for effective UV water sterilisation, while shielding the lamp from direct contact with water.
This quartz sleeve is a direct compatible replacement for Sterilight QS-950 and is suitable for use in SPV-950, SPV-20, and SP950-HO UV systems.
Key Features & Benefits
-
High UV Transmittance Quartz
Allows optimal UV-C light output for effective disinfection of bacteria, viruses, and pathogens. -
Domed End Design
Engineered to fit correctly within compatible Sterilight and Viqua UV chambers, ensuring proper lamp positioning. -
Protects UV Lamp
Prevents water contact with the UV bulb, extending lamp life and maintaining system safety. -
Essential UV System Component
A clean, undamaged quartz sleeve is critical for maintaining UV dose and system performance. -
Compatible Replacement Part
Designed for Sterilight / Viqua Platinum & Cobalt UV systems.
Compatible UV Systems
-
Sterilight SPV-950
-
Sterilight SPV-20
-
Sterilight SP950-HO
-
Viqua Platinum & Cobalt series (model dependent)
Always confirm your existing quartz sleeve reference and system model before ordering.
Technical Specifications
| Feature | Specification |
|---|---|
| Product Code | QS-950 |
| Material | High-transmittance quartz glass |
| Length | Approx. 1082 mm |
| End Type | Domed |
| Replacement Interval | Typically every 24 months |
| Application | UV water disinfection systems |
Maintenance & Replacement Guidance
Quartz sleeves should be:
-
Replaced every 24 months, or sooner if
-
They become etched, cloudy, cracked, or cannot be fully cleaned
A compromised quartz sleeve can significantly reduce UV effectiveness, even if the lamp is functioning correctly.
Why Buy UV Quartz Sleeves from Wrekin Water?
-
Specialist supplier of UV water filtration parts
-
Stocked replacement quartz sleeves for top UV brands
-
Expert technical advice if you’re unsure of compatibility
-
Fast UK dispatch with reliable support
Product Documents
Product Documents
All our orders are sent with tracked courier services
Free Customer Support by experts

QS-950 - Domed End Compatible Viqua Sterilight Quartz Sleeve, SPV-950, SPV-20, and SP950-HO (QJ231082DE)
Frequently asked questions
For full details on returns, refunds, eligibility, and timeframes, please refer to our complete Refund Policy here:
👉 Refund and Returns Policy
If you are unsure whether your item qualifies for return, please contact our team before sending anything back and we’ll be happy to help.
Your UV quartz sleeve should be inspected every 12 months when changing your UV lamp. A UV quartz sleeve used in an ultra violet light water treatment system does not always need annual replacement, but it must be cleaned and checked for limescale, staining or cracks. If the quartz sleeve becomes cloudy, etched or damaged, it should be replaced immediately to maintain proper UV transmission and effective water disinfection.
A UV quartz sleeve protects the UV lamp inside your ultra violet light system while allowing maximum UV light transmission into the water. The quartz sleeve creates a waterproof barrier between the electrical UV lamp and the flowing water, ensuring safe and efficient UV disinfection. Without a clean and intact UV quartz sleeve, the ultra violet light cannot effectively neutralise bacteria, viruses and microorganisms.
Yes. Limescale, iron and manganese buildup can coat the UV quartz sleeve and reduce the amount of ultra violet light passing through the glass. This reduces UV performance and can compromise water safety. In hard water areas, regular cleaning of your UV quartz sleeve is essential to maintain optimal UV output and ensure your ultra violet light system continues to operate correctly.
QS-950 - Domed End Compatible Viqua Sterilight Quartz Sleeve, SPV-950, SPV-20, and SP950-HO (QJ231082DE)
Sterilight QS-950 Quartz Sleeve – Compatible with Viqua & Sterilight UV Systems
High-Transmittance UV Quartz Sleeve for Reliable Water Sterilisation
The Sterilight QS-950 Quartz Sleeve is a high-quality, domed UV quartz sleeve designed to protect and house the UV lamp within Viqua / Sterilight Platinum and Cobalt series UV systems. Manufactured from high-transmittance quartz glass, this sleeve ensures maximum UV light penetration for effective UV water sterilisation, while shielding the lamp from direct contact with water.
This quartz sleeve is a direct compatible replacement for Sterilight QS-950 and is suitable for use in SPV-950, SPV-20, and SP950-HO UV systems.
Key Features & Benefits
-
High UV Transmittance Quartz
Allows optimal UV-C light output for effective disinfection of bacteria, viruses, and pathogens. -
Domed End Design
Engineered to fit correctly within compatible Sterilight and Viqua UV chambers, ensuring proper lamp positioning. -
Protects UV Lamp
Prevents water contact with the UV bulb, extending lamp life and maintaining system safety. -
Essential UV System Component
A clean, undamaged quartz sleeve is critical for maintaining UV dose and system performance. -
Compatible Replacement Part
Designed for Sterilight / Viqua Platinum & Cobalt UV systems.
Compatible UV Systems
-
Sterilight SPV-950
-
Sterilight SPV-20
-
Sterilight SP950-HO
-
Viqua Platinum & Cobalt series (model dependent)
Always confirm your existing quartz sleeve reference and system model before ordering.
Technical Specifications
| Feature | Specification |
|---|---|
| Product Code | QS-950 |
| Material | High-transmittance quartz glass |
| Length | Approx. 1082 mm |
| End Type | Domed |
| Replacement Interval | Typically every 24 months |
| Application | UV water disinfection systems |
Maintenance & Replacement Guidance
Quartz sleeves should be:
-
Replaced every 24 months, or sooner if
-
They become etched, cloudy, cracked, or cannot be fully cleaned
A compromised quartz sleeve can significantly reduce UV effectiveness, even if the lamp is functioning correctly.
Why Buy UV Quartz Sleeves from Wrekin Water?
-
Specialist supplier of UV water filtration parts
-
Stocked replacement quartz sleeves for top UV brands
-
Expert technical advice if you’re unsure of compatibility
-