Product Description

WrekinWater supplies this replacement quartz sleeve for the larger Atlas H151 UV disinfection system, which is also sold as the Luminor RQ-950. The domed-end sleeve arrives complete with its O-ring, ready to swap in for a sleeve that has clouded, scaled or become discoloured with use.

Compatible systems Atlas H151 / Luminor RQ-950
Sleeve end style Domed end
Includes O-ring seal
Material High-purity UV-transparent quartz glass
SKU RQ-H151
Recommended replacement interval Approx. every 12 months

Signs your quartz sleeve needs replacing

  • Visible scaling, cloudiness or fine scratches along the sleeve.
  • A brownish or yellow discolouration you can see through the glass.
  • Water starts to taste or smell slightly off even though the lamp still lights.
  • The UV monitor alarm sounds despite the lamp appearing to work normally.

The quartz sleeve on the H151/RQ-950 separates the UV lamp from the water flowing past it while allowing UV-C light to pass through and disinfect it. Limescale, iron staining or surface scratches on the quartz reduce how much of that light gets through, so the system can keep running with the lamp lit while disinfection quietly becomes less effective.

As a family run business based in Bettisfield, Shropshire with over 15 years and 50,000-plus customers behind it, WrekinWater stocks the correct part sizes for larger UV systems like the H151/RQ-950 so you're not guessing between similar-looking sleeves. Customers rate the service "Excellent" on Trustpilot.

How to replace it

  1. Isolate the water supply to the UV housing and switch off the unit.
  2. Drain the chamber, then undo the retaining nut or union cap at the base.
  3. Withdraw the UV lamp first, then carefully slide out the old quartz sleeve.
  4. Clean the inside of the housing and fit the new O-ring before inserting the new sleeve.
  5. Refit the lamp, reassemble the union or retaining nut, and restore power and water.
  6. Run the system to drain briefly before using the water again.

Have You Ordered Before?

Existing/previous customers can find their previous orders with just a surname and a postcode. There’s no better way to find parts and replacements!

Get Started
RQ-H151 - Atlas H151 Replacement Quartz Sleeve and Luminor RQ-950

RQ-H151 - Atlas H151 Replacement Quartz Sleeve and Luminor RQ-950

Regular price £96.00 inc. VAT
£80.00 ex. VAT
Sale price £96.00 inc. VAT
£80.00 ex. VAT

Frequently asked questions

For full details on returns, refunds, eligibility, and timeframes, please refer to our complete Refund Policy here:

👉 Refund and Returns Policy

If you are unsure whether your item qualifies for return, please contact our team before sending anything back and we’ll be happy to help.

Yes, the RQ-H151 sleeve is built to the same specification used in the Luminor RQ-950, as the Atlas H151 and RQ-950 are the same UV system under different branding.

The O-ring is included with this sleeve, so no separate purchase is needed for a standard replacement.